Resultado da pesquisa (4)

Termo utilizado na pesquisa indirect fluorescent antibody test

#1 - Sarcocystis spp. detection in cattle using different diagnostic methods

Abstract in English:

Cattle are considered intermediate hosts of Sarcocystis, which can cause clinical signs and lower performance in the acute phase of infection. Sarcocystis spp. are usually not visible to the naked eye during the post mortem inspection. Moreover, fresh microscopic examination and transmission electron microscopy techniques are difficult to apply to large samples. Therefore, extensive studies on Sarcocystis infection in cattle using molecular and serological methods are required. Here, we investigated Sarcocystis spp. infection in cattle using fresh microscopic examination and polymerase chain reaction of myocardium samples and compared the results with the presence of antibodies against Sarcocystis spp. in corresponding serum samples detected using indirect fluorescent antibody test. Microscopic Sarcocystis were observed in 100% of the myocardial samples, and Sarcocystis DNA was present in 86% (43/50) of these samples. Antibodies against Sarcocystis spp. were detected in 96% (48/50) and 80% (40/50) of the serum samples at 1:25 and 1:200 dilutions, respectively. The three associated methods (fresh microscopic examination, PCR and serology) showed good sensitivity and detection for Sarcocystis spp. compared with fresh microscopic examination (only), and they may facilitate diagnosis in live animals on a large scale as well as monitoring of the herd status.

Abstract in Portuguese:

Os bovinos são considerados hospedeiros intermediários de Sarcocystis, podendo causar sinais clínicos e menor desempenho na fase aguda da infecção. Sarcocystis spp. geralmente não são visíveis a olho nu durante a inspeção post mortem. Além disso, o exame microscópico a fresco e as técnicas de microscopia eletrônica de transmissão são difíceis de aplicar a uma amostras de grande tamanho. Portanto, são necessários extensos estudos sobre a infecção por Sarcocystis em bovinos usando métodos moleculares e sorológicos. Aqui, investigamos a infecção de Sarcocystis spp. em bovinos por meio de exame microscópico a fresco e reação em cadeia da polimerase de amostras de miocárdio e comparado os resultados com a presença de anticorpos contra Sarcocystis spp. em amostras de soro correspondentes detectadas usando o teste de anticorpos fluorescentes indiretos. Sarcocistos microscópicos foram observados em 100% das amostras de miocárdio, e o DNA de Sarcocystis estava presente em 86% (43/50) dessas amostras. Anticorpos contra Sarcocystis spp. foram detectados em 96% (48/50) e 80% (40/50) das amostras de soro nas diluições 1:25 e 1:200, respectivamente. Os três métodos associados (exame microscópico a fresco, PCR e sorologia) mostraram boa sensibilidade e detecção para Sarcocystis spp. em comparação com o exame microscópico fresco (apenas) e podem facilitar o diagnóstico em animais vivos em larga escala, bem como o monitoramento do status do rebanho.


#2 - Serodiagnosis of Babesia equi in horses submitted to exercise stress, p.179-183

Abstract in English:

ABSTRACT.- Baldani C.D., Machado R.Z., Raso T.F. & Pinto A.A. 2007. Serodiagnosis of Babesia equi in horses submitted to exercise stress. Pesquisa Veterinária Brasileira27(4):179-183. Departamento de Patologia Veterinária, Universidade Estadual Paulista, Faculdade de Ciências Agrárias e Veterinárias, Via de Acesso Prof. Paulo Donato Castellane s/n, Jaboticabal, SP 14870-000, Brazil. E-mail: zacarias@fcav.unesp.br A complement fixation test (CFT), performed in microtitre plates, based upon the use of crude antigenic preparation of Babesia equi was adapted for the detection of antibodies in serum of infected horses. The indirect fluorescent antibody test (IFAT) and enzyme-linked immunosorbent assay (ELISA) were also used for the immunodiagnosis of B. equi. Serum samples from 15 apparently healthy horses, previously conditioned to a high-speed equine treadmill, were taken before and after exercise. All the samples analyzed were positive for B. equi infection. There were no significant differences (P<0.01) between these 3 tests, or the condition of rest or stress. The combined use of CFT and IFAT or ELISA should be recommended in order to enable veterinary services to more efficiently prevent introduction of infected horses into disease-free areas.

Abstract in Portuguese:

ABSTRACT.- Baldani C.D., Machado R.Z., Raso T.F. & Pinto A.A. 2007. Serodiagnosis of Babesia equi in horses submitted to exercise stress. Pesquisa Veterinária Brasileira27(4):179-183. Departamento de Patologia Veterinária, Universidade Estadual Paulista, Faculdade de Ciências Agrárias e Veterinárias, Via de Acesso Prof. Paulo Donato Castellane s/n, Jaboticabal, SP 14870-000, Brazil. E-mail: zacarias@fcav.unesp.br A complement fixation test (CFT), performed in microtitre plates, based upon the use of crude antigenic preparation of Babesia equi was adapted for the detection of antibodies in serum of infected horses. The indirect fluorescent antibody test (IFAT) and enzyme-linked immunosorbent assay (ELISA) were also used for the immunodiagnosis of B. equi. Serum samples from 15 apparently healthy horses, previously conditioned to a high-speed equine treadmill, were taken before and after exercise. All the samples analyzed were positive for B. equi infection. There were no significant differences (P<0.01) between these 3 tests, or the condition of rest or stress. The combined use of CFT and IFAT or ELISA should be recommended in order to enable veterinary services to more efficiently prevent introduction of infected horses into disease-free areas.


#3 - Evaluation of the indirect fluorescent antibody test and modified agglutination test for detection of antibodies against Toxoplasma gondii in experimentally infected pigs

Abstract in English:

Minho A.P., Navarro I.T., Freire R.L., Vidotto O., Gennari S.M., Marana E.M. & Garcia J.L. 2004. Evaluation of the indirect fluorescent antibody test and modified agglutination test for detection of antibodies against Toxoplasma gondii in experimentally infected pigs. Pesquisa Veterinária Brasileira 24(4):199-202. Depto Medicina Veterinária Preventiva, Universidade Estadual de Londrina, Cx. Postal 6001, Londrina, PR 86050-970, Brazil. E-mail: italmar@uel.br The study determined the sensitivity and specificity of the indirect fluorescent antibody test (IFAT) and modified agglutination test (MAT) for anti-Toxoplasma gondii antibody detection by analyzing sera from 46 experimentally infected pigs. Values for sensitivity were 95.7% (confidence interval 95%: 84.0-99.2%) and for specificity 97.8% (confidence interval 95%: 87.0-99.9%) in both tests. There was an optimum agreement of results between IFAT and MAT evidenced by a Kappa test of 0.86. These results validate these tests for the detection of T. gondii infection in pigs. IFAT and MAT despite methodologies with different characteristics and readings have similar accuracy in pig serum samples.

Abstract in Portuguese:

Minho A.P., Navarro I.T., Freire R.L., Vidotto O., Gennari S.M., Marana E.M. & Garcia J.L. 2004. Evaluation of the indirect fluorescent antibody test and modified agglutination test for detection of antibodies against Toxoplasma gondii in experimentally infected pigs. Pesquisa Veterinária Brasileira 24(4):199-202. Depto Medicina Veterinária Preventiva, Universidade Estadual de Londrina, Cx. Postal 6001, Londrina, PR 86050-970, Brazil. E-mail: italmar@uel.br The study determined the sensitivity and specificity of the indirect fluorescent antibody test (IFAT) and modified agglutination test (MAT) for anti-Toxoplasma gondii antibody detection by analyzing sera from 46 experimentally infected pigs. Values for sensitivity were 95.7% (confidence interval 95%: 84.0-99.2%) and for specificity 97.8% (confidence interval 95%: 87.0-99.9%) in both tests. There was an optimum agreement of results between IFAT and MAT evidenced by a Kappa test of 0.86. These results validate these tests for the detection of T. gondii infection in pigs. IFAT and MAT despite methodologies with different characteristics and readings have similar accuracy in pig serum samples.


#4 - Development of an enzyme-linked immunosorbent assay for the detection of antibodies against Babesia bovis, 20(4):167-170

Abstract in English:

ABSTRACT.- Madruga C.R., Araújo F.R., Marques A.P.C., Carvalho C.M.E., Cusinato F.Q., Crocci A.J., Kessler R.H. & Miguita M. 2000. [Development of an enzyme-linked immunosorbent assay for the detection of antibodies against Babesia bovis.] Desenvolvimento de uma prova de imunoadsorção enzimática para detecção de anticorpos contra Babesia bovis. Pesquisa Veterinária Brasileira 20(4):167-170. Embrapa Gado de Corte, BR 262 Km 4, Campo Grande, MS 79002-970, Brazil. An enzyme-linked immunosorbent assay (ELISA) for antibodies to Babesia bovis was developed and evaluated in comparison with the indirect fluorescent antibody test (IFAT). The ELISA sensitivity and specificity, estimated with 100 positive sera from cattle experimentally infected with B. bovis and 108 negative sera collected from B. bovis-free herds, were 98.0% and 98.1 %, respectively. Positive and negative predictive values were, respectively, 98.0% and 98.1 %, and precision was 98.1 %. No cross-reactions were detected with 80 sera from calves experimentally inoculated with Babesia bigemina. The ELISA was compared with IFAT using 110 cattle sera from an enzootically stable area and with 168 cattle sera from an enzootically unstable area. In both cases, there was a significant agreement between results of both tests (P=0.631 and 0.4725, respectively). In an epidemiological study performed with ELISA in the Pantanal region of the State of Mato Grosso do Sul with 1,365 cattle sera, 83.9%were positive for antibodies against B. bovis, characterizing this region as enzootically stable.

Abstract in Portuguese:

RESUMO.- Madruga C.R., Araújo F.R., Marques A.P.C., Carvalho C.M.E., Cusinato F.Q., Crocci A.J., Kessler R.H. & Miguita M. 2000. [Development of an enzyme-linked immunosorbent assay for the detection of antibodies against Babesia bovis.] Desenvolvimento de uma prova de imunoadsorção enzimática para detecção de anticorpos contra Babesia bovis. Pesquisa Veterinária Brasileira 20(4):167-170. Embrapa Gado de Corte, BR 262 Km 4, Campo Grande, MS 79002-970, Brazil. Uma prova de imunoadsorção enzimática (ELISA) para detecção de anticorpos contra Babesia bovis foi desenvolvida e avaliada em comparação à imunofluorescência indireta (IFI). A sensibilidade e especificidade do ELISA, determinadas pela análise de 100 soros positivos de bovinos infectados experimentalmente com B. bovis e 108 soros negativos colhidos de bovinos livres de infecção por este hemoparasito, foram de 98,0% e 98, 1 %, respectivamente. Os valores preditivos positivo e negativo foram, respectivamente, 98,0% e 98, 1 % e a precisão do teste foi de 9.8, 1 %. Não foram detectadas reações cruzadas com 80 soros de bezerros experimentalmente inoculados com Babesia bigemina. O ELISA foi comparado à IFI usando 110 soros de rebanhos de área de estabilidade endêmica e 168 soros de rebanhos de áreas de instabilidade endêmica. Em ambos os casos, houve concordância significativa (P=0,631 e 0,4725, respectivamente) entre os resultados demonstrados pelos dois testes. Em um estudo epidemiológico realizado com o ELISA na região do Pantanal de Mato Grosso do Sul, com 1.365 soros de bovinos, 83,9% foram positivos para anticorpos contra B. bovis, caracterizando a região estudada como endemicamente estável.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV